MSDS Number: P12698V 

  1. Product Identification
    Manufacturer: CQ Concepts
    Phone: (815)-759-3991
    Fax: (815)-759-3996
    Prod #: 695
    Address: 4004 Dayton St. Mchenry, IL 60050
    Emergency Phone: infotrac 1-800-535-5053
    Trade Name: Aqua Ammonia
    Product Type: (Ammonia Hydroxide Solution)
  2. Composition/Information on Ingredients
    Chemical Name/
    Common Name

    CAS No.
    Percent (Optional)
    TLV (Source)
    -----------------------------
    ---------
    ------------
    Ammonium Hydroxide
    1336-21-6
    4
    Water
    7732-18-5
    96
  3. Physical Data
    Boiling Point (f) : 27- deg c / 80 deg f
    Specific Gravity (h2o=1.0): .9825
    Degree Baume: 12.35
    Vapor Pressure (mm hg): 590 @ 100 deg f
    Vapor Density: .59 @ 32 Deg f
    Appearance: colorless
    Odor: pungent

    Solubility in Water: negligible
    _x_complete ____insoluble ____emulsifiable ____slight

    Evaporation Rate(vsh2o): n/a
    ___faster ____slower _____ about the same

    Appearance: clear liquid
  4. Fire and Explosion Hazard Data
    Flash Point (t.C.C.): None.
    Flammable Limits: n/a
    Extinguishing Media: water, dry chemical, or co2
    Explosion: not considered an explosion hazard Fire: not considered to be a fire hazard
    Special Information: full prorecti clothing and self contained breathing apparatus NIOSH approved
  5. Reactivity Data
    Stability: stable under ordinary conitions of use and storage
    Hazardous Decomposition Products: mixing with household bleach will cause a dangerous production of chlorine gas and oxygen.
    Hazardous Polymerization: this substance does not polymerize.
    Incompatibilities:
    • conditions to avoid: reacts vigorously with bleach
    • materials to avoid: sliver, mercury, copper, zinc
  6. Health Hazard Data
    OSHA Permissible Exposure Limit: tlv 50 ppm
    Carcinogen - NTP Program: n/a
    ACGIH Threshold Limit Value : n/a
    Carcinogen - IARC Program: n/a
    Systoms of Exposure: general discomfort & eye tearing; no lasting effect on short exposure. 400-700 Ppm
  7. Emergency and First Aid Procedures
    Eyes: flush holding eyelids open with water for at least 15 minutes a 5% boric acid solution mat be used in place of water. Immedate response is essential. Call a physician immediately.

    Skin: wash affected areas with large amounts of water while removing contaminated clothing. Do not alpply salves or ointment or cover burns with dressing. Injured areas should be covered with clean cloth prior to medical care. Do not attempt to neutralize the ammonium hydrxide. Call a physician.

    Ingestion: drink large amounts of water followed by neutralzing agents such as dilute vinegar, lemon juice, orange juice, grapefruit juice or lime juice. Induce vomiting. Call a physician immediately.

    Inhalation: move exposed person to fresh air, if not breathing perform artificial respiration, keep warm, get medical help immediately advise physician not to use adrenalin.
  8. Special Protection Information
    Respiratory Protection: use a full face piece respirator
    Ventilation Requirements: maximum ventilation
    Eye Protection: approate eye and face protection required
    Protective Gloves: noeprene, viton, pva or pvc coated gloves
    Other Protective Clothing: aprons and other protective clothing
    eye wash station should be available in work area.
  9. Spill or Leak Procedures
    Spill Response: contain spill to minimize ammonia vaporization.
    Waste Disposal Methods: dilute with water and flush to local sewer system, if permitted. Solid waste must be disposed of in a pemitted waste management facility. Ensure compliance with local, state, and federal regulations.
  10. Storage and Handling Information
    Store in cool, dry, ventilated area. Protect against physical damage. Keep separate from incompatibles. Keep out of reach of children.

    *NOTICE: The information givin herein is provided in good faith and is belived to be correct as of the date hereof. However, CQ Concepts makes no representation as to the comprehensivness or accuracy of the information. It is expected that the indiviuals receiving the information will exercise their independent judgement in deternining its appropriateness for a particular purpose. Accordingly CQ Concepts will not be responsible for damages of any kind resulting from the use of or reliance upon such information. No representations, or warranties, either express or implied, of merchantability, fitness for particular purpose or of any other nature are made hereunder with respect to the information set forth herein or to the product to which the information refers.